ST03A - Troubleshooting -> V2.4.07
- Download always fails via the serial RS-232 connection of the MB04B board
- On some computers a timing related problem causes the software installation to fail if ST03A is connected via an RS232 cable to an MB04B board. You can download for free of charge the Service Pack 1 for ST03A V2.4.07 that fixes the software installation problem.
- Cannot open measurement file - 1
- ST03A V2.4.07 may not be able to open a previously saved measurement file (*.xmd) if special SU05A channels were measured together with ESRA variables.
A software patch is available here to enable you to restore your saved measurements.
-
- Download the MeasurementConfiguration.zip file from the Downloads page.
- Extract the downloaded file to MeasurementConfiguration.xsd. The extracted file should be 42 018 bytes long.
- Overwrite your existing MeasurementConfiguration.xsd file with the recently downloaded one. Typically you can find the original MeasurementConfiguration.xsd file in the C:\Program Files\KnorrBremse\ST03A V2.4.07\xml folder of your computer.
- Start your ST03A V2.4.07 and open the measurement file (*.xmd).
- Cannot open measurement file - 2
- Application request parameters are not changed / I'm not sure if I could set the wheel diameter correctly...
- Some applications support the current parameter value read back operation while others not.
If an application does not support this feature then ST03A will display default request parameter values that are coming from the project file instead of the current parameter values used within the ESRA system.
This leads to a situation where the displayed parameter value (e.g. wheel diameter) differs from the currently used value.
This behavior may confuse the user.
The resolution of the problem typically requires both changes in the application software and in the ST03A project file. - The saved measurement data file contains corrupt data which are not equal with the original measured data
- This problem occurs if the graphic view is changed during file saving process (e.g. by scrolling, zooming, fitting window etc.).
- To avoid this problem don’t do anything during the saving process, which state is shown by progress bar on the right bottom corner in the main window.