V2.3.07 troubleshooting

Note: This version is not supported any more, please use V3 versions instead.

Application requests work incorrectly

This problem appears in ST03A V2.3.07 when you have a project file containing more than one application with application requests.

The problem is that ST03A V2.3.07 always takes the parameters from the parameter list of the first application. This means that the first parameter of the first application request of the second application is replaced by the first parameter of the first application request of the first application before transmission.

The best solution is to upgrade to a newer ST03A version. ■

The saved measurement data file contains corrupt data which are not equal with the original measured data

This problem occurs if the graphic view is changed during file saving process (e.g. by scrolling, zooming, fitting window etc.).

To avoid this problem don't do anything during the saving process, which state is shown by progress bar on the right bottom corner in the main window. ■

ST03A V2 versions